How to change the flow direction on SK steam trap


#4 How to change the flow direction on SK steam trap



  1. Release crosswise the 4 cover screws
  2. Remove the 4 cover screws
  3. Remove the cover
  4. Replace the damaged body gasket
  5. Rotate the cover a quarter turn as shown
  6. Put the cover back in
  7. Put back the 4 cover screws & tighten crosswise
  8. When installing horizontally, the body and cover arrows must be perpendicular
  9. When installing vertically (downflow only), the body and cover arrows must be parallel